Script for monitoring: RTTC cable of DU
Quoting Giorgio:
For calibration check purposes it would be very useful to have a check of the RTTC (Cable round trip time) of the DU bases during the detector running.
This parameter is easily calculated using the White rabbit parameters stored during DU operation into the DB:
wr_mu-(wr_delta[0]+wr_delta[1]+wr_delta[2]+wr_delta[3])