#!/usr/bin/env python
# coding=utf-8
# Filename: pmt_hrv.py
# Author: Tamas Gal <tgal@km3net.de>
# vim: ts=4 sw=4 et
"""
Monitors HRV flags of PMTs.
Usage:
pmt_hrv.py [options]
pmt_hrv.py (-h | --help)
Options:
-l LIGIER_IP The IP of the ligier [default: 127.0.0.1].
-p LIGIER_PORT The port of the ligier [default: 5553].
-u DU The DU to monitor [default: 1].
-d DET_ID Detector ID [default: 29].
-i INTERVAL Time interval for one pixel [default: 10].
-o PLOT_DIR The directory to save the plot [default: plots].
-h --help Show this screen.
"""
from datetime import datetime
import io
import os
from collections import defaultdict
import threading
import time
import numpy as np
import matplotlib
matplotlib.use('Agg')
import km3pipe as kp
from km3pipe.io.daq import TMCHData
import matplotlib.pyplot as plt
import km3pipe.style as kpst
kpst.use("km3pipe")
__author__ = "Tamas Gal"
__email__ = "tgal@km3net.de"
VERSION = "1.0"
log = kp.logger.logging.getLogger("PMTrates")
def configure(self):
self.detector = self.require("detector")
self.du = self.require("du")
self.interval = self.get("interval", default=10)
self.plot_path = self.get("plot_path", default="plots")
self.filename = self.get("filename",
default=f"pmt_hrv_du{self.du}.png")
self.max_x = 800
self.index = 0
self.hrv = defaultdict(list)
self.lock = threading.Lock()
self.thread = threading.Thread(target=self.run, args=())
self.thread.daemon = True
self.thread.start()
def run(self):
interval = self.interval
while True:
time.sleep(interval)
now = datetime.now()
self.add_column()
self.update_plot()
with self.lock:
self.rates = defaultdict(list)
delta_t = (datetime.now() - now).total_seconds()
remaining_t = self.interval - delta_t
log.info("Delta t: {} -> waiting for {}s".format(
delta_t, self.interval - delta_t))
if (remaining_t < 0):
log.error("Can't keep up with plot production. "
"Increase the interval!")
interval = 1
else:
interval = remaining_t
def add_column(self):
m = np.roll(self.hrv_matrix, -1, 1)
mean_hrv = np.full(y_range, np.nan)
for i in range(y_range):
if i not in self.hrv:
continue
mean_hrv[i] = np.mean(self.hrv[i])
m[:, self.max_x - 1] = mean_hrv
self.hrv_matrix = m
def update_plot(self):
filename = os.path.join(self.plot_path, self.filename)
print("Updating plot at {}".format(filename))
now = time.time()
max_x = self.max_x
interval = self.interval
def xlabel_func(timestamp):
return datetime.utcfromtimestamp(timestamp).strftime("%H:%M")
m = self.hrv_matrix
fig, ax = plt.subplots(figsize=(10, 8))
ax.imshow(m, origin='lower', interpolation='none')
ax.set_title("HRV Ratios (Monitoring Channel) for DetID-{} DU-{}\n"
"PMTs ordered from top to bottom - {}".format(
self.detector.det_id, self.du, datetime.utcnow()))
xtics_int = range(0, max_x, int(max_x / 10))
plt.xticks(
[i for i in xtics_int],
[xlabel_func(now - (max_x - i) * interval) for i in xtics_int])
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
fig.tight_layout()
plt.savefig(filename)
plt.close('all')
def process(self, blob):
try:
tmch_data = TMCHData(io.BytesIO(blob['CHData']))
except ValueError:
self.log.error("Could not parse binary data. Ignoring...")
return blob
dom_id = tmch_data.dom_id
if dom_id not in self.detector.doms:
return blob
du, floor, _ = self.detector.doms[dom_id]
if du != self.du:
return blob
hrv_flags = reversed("{0:b}".format(tmch_data.hrvbmp).zfill(32))
y_base = (floor - 1) * 31
for channel_id, hrv_flag in enumerate(hrv_flags):
if channel_id > 30:
break
idx = y_base + kp.hardware.ORDERED_PMT_IDS[channel_id]
with self.lock:
self.hrv[idx].append(int(hrv_flag))
return blob
def main():
from docopt import docopt
args = docopt(__doc__, version=VERSION)
det_id = int(args['-d'])
plot_path = args['-o']
ligier_ip = args['-l']
ligier_port = int(args['-p'])
du = int(args['-u'])
interval = int(args['-i'])
detector = kp.hardware.Detector(det_id=det_id)
pipe = kp.Pipeline(timeit=True)
pipe.attach(kp.io.ch.CHPump,
host=ligier_ip,
port=ligier_port,
tags='IO_MONIT',
timeout=60 * 60 * 24 * 7,
max_queue=2000)
pipe.attach(PMTHRV,
detector=detector,
du=du,
interval=interval,
plot_path=plot_path)